IDENTIFICATION OF WHITE NOISE AND 1/f IN CURRENT MIRROR CONFIGURATION BASED ON VDS MOSFET

Authors

  • Maria Rosariana Gea
  • Lazuardi Umar University of Riau
  • Rahmondia Nanda Setiadi

DOI:

https://doi.org/10.22437/jop.v7i2.18167

Keywords:

Keywords : Biosensor, Current Mirror; MOSFET BS250; White and 1/f Noise

Abstract

Identifying noise in the Current Mirror (CM) circuit is essential to locate noise signals in biosensor applications so that measurements become more accurate and precise. There are two dominant types of noise: white noise, which consists of thermal noise and shot noise, and also low-frequency noise (1/f  noise). The main component of the CM circuit is the BS250 type MOSFET, which works by varying the width of the charge carrier channelcontrolled by the voltage at the gate. When the drain is given a voltage, electrons will flow from the source to the drain which generates the noise.This study was carried out to identify the noise in the CM configuration by varying the reference voltage of MOSFET using the PCI-6221 card data integrated with the LabVIEW program. The reference voltage values ​​used are 1 mV, 10 mV, and 100 mV to determine the effect of the input voltage on the CM circuit noise signal, while the measurement frequency is varied from 0.1 Hz to 100 kHz with a resolution of 0.1 Hz. The results show that the noise characteristics vary with the applied voltage, which will increase at a higher voltage. Analysis of 1/f noise at frequencies up to 0.2 Hz has a gradient increase of up to 10 times for each given voltage value. Based on the value of the data distribution on the white noise measurement, it shows that a voltage of 100 mV produces the highest noise with an average of 3.62 × 10-7 Vrms/Hz1/2. The results of this study are used in the design of CM circuits with minimal noise.

Downloads

Download data is not yet available.

References

Aggarwal, B., Gupta, M., & Gupta, A. K. (2016). A comparative study of various current mirror configurations: Topologies and characteristics. Microelectronics Journal, 53, 134-155.

Barkhordarian, V. (1996). Power MOSFET basics. Powerconversion and Intelligent Motion-English Edition, 22(6), 2-8.

Beenakker, C. W. J., & Schonenberger, C. (2006). Quantum shot noise. arXiv preprint cond-mat/0605025.

Kiely, B.R. (2017). Understanding and Eliminating 1 / f Noise. (May). Hal. 3–6

Silvaco .(2009). Noise Modeling in MOSFET and Bipolar Devices Noise Modeling - MOSFET Noise. Silvaco.

Singh, M. & Sarma, R. (2018). Design and implementation of MOSFET Based Folded Cascode Current Mirror. Proceedings - 2nd International Conference on Intelligent Circuits and Systems, ICICS 2018, (April). Hal. 22–27.

Vasilescu, G. (2005). Electronic noise and interfering signals: principles and applications. Springer Science & Business Media. Hal 1-12.

Wang, Z., Chen, Y., Patil, A., Jayabalan, J. dan Zhang, X. (2017). Current Mirror Array : A Novel Circuit Topology for Combining Physical Unclonable Function and Machine Learning. Hal. 1–13

Wati, A., Setiadi, R. N., & Umar, L. (2021, March). Noise characterization of MOSFET current mirror circuit on high impedance application using DAQ card PCI-6221. In AIP Conference Proceedings (Vol. 2320, No. 1, p. 050001). AIP Publishing LLC.

Wilamowski, B. M., & Irwin, J. D. (Eds.). (2018). Fundamentals of industrial electronics. CRC Press. Hal 58-62.

Umar, L., Hamzah, Y. dan Setiadi, R.N. (2019). Biosensor signal improvement using current mirror topology for dissolved oxygen measurement. Measurement Science and Technology. Vol. 30, no. 6, hal. 1-9. https://doi.org/10.1088/1361-6501/ab0675

Ziegler, C., & Göpel, W. (1998). Biosensor development. Current opinion in chemicalbiology, 2(5),585

Downloads

Published

2022-06-23

How to Cite

Gea, M. R., Umar, L., & Setiadi, R. N. (2022). IDENTIFICATION OF WHITE NOISE AND 1/f IN CURRENT MIRROR CONFIGURATION BASED ON VDS MOSFET. JOURNAL ONLINE OF PHYSICS, 7(2), 40-47. https://doi.org/10.22437/jop.v7i2.18167